Search found 128 matches

by nama
Tue Sep 05, 2017 9:38 am
Forum: SALES
Topic: I want to swap ZX80 for Spectrum 128k (Toast rack)
Replies: 2
Views: 2847

I want to swap ZX80 for Spectrum 128k (Toast rack)

Fire me an private message if interested.

Cheers
Phil
by nama
Mon Sep 04, 2017 8:32 am
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

Ok, I spoke a little too soon. After about 20 seconds the pixels started to creep. Adding a capacitor to GND helped fix this (as Pokemon suggested) Fortunately it works well in the issue 3, but unfortunately not in my issue 1 where the characters are still all weird. So It'll stay in the issue 3. IM...
by nama
Sun Sep 03, 2017 11:21 pm
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

I was just trying out the thought about touching the ROMCS line, unfortunately it didn't seem to work....However while doing this I had another serendipitous moment. The lead going to pin 6 of the 74LS02 dropped off, and the 'K' cursor instantly cleared up. Then I connected this line to GND and agai...
by nama
Sun Sep 03, 2017 9:32 am
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

I just built up Marks circuit using a 74LS02.
Have a look at this...It's even more dynamic

https://www.youtube.com/watch?v=zg1Gymf ... e=youtu.be

Phil
by nama
Sun Sep 03, 2017 6:29 am
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

Me again,
I tried 2 things:
1) plugged in the ZXpand. It looked perfect...

IMG_6159.JPG
IMG_6159.JPG (29.1 KiB) Viewed 4099 times
2) plugged in the keyboard with no ZXpand...
IMG_6160.JPG
IMG_6160.JPG (28.43 KiB) Viewed 4099 times
by nama
Sun Sep 03, 2017 5:34 am
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

Hi guys, So I connected the ROM CS line to the 680 Ohm resistor instead of directly to the ROM pin 20. This helped, now I can connect GND to the 74LS32 and still get the cursor. In fact the 'K' cursor first appears perfectly formed, then after a few seconds pixels start to flicker off. Strangely thi...
by nama
Sun Sep 03, 2017 3:55 am
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

Yes, very strange indeed.
Here is a pic of the cursor without the GND line attached to the 74LS32.
IMG_6156.PNG
IMG_6156.PNG (115.72 KiB) Viewed 4110 times
Sometime it looks more formed than this, and other times worse.

As I mentioned previously, if I connect the GND line up then the screen become blank again.

Phil
by nama
Sun Sep 03, 2017 12:12 am
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

Just racing out the door, but wanted to get this out there quickly. Firstly thanks for the great ideas. I quickly built Andy's circuit using jumper wires, and lifting pin 13 in the ULA. At first it didn't work...still a blank white screen. Then I accidentally knocked the GND wire off the 7432 and I ...
by nama
Sat Sep 02, 2017 1:51 am
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

Hi Andy,
Can you briefly explain how that would be hooked up?

Cheers

Philip
by nama
Fri Sep 01, 2017 10:24 pm
Forum: Hardware
Topic: White screen of death
Replies: 33
Views: 13617

Re: White screen of death

Thanks again for the reply.
Would something like this work?
Screen Shot 2017-09-02 at 8.15.55 AM.jpg
Screen Shot 2017-09-02 at 8.15.55 AM.jpg (41.99 KiB) Viewed 2836 times
One question.
If the issue is the CS line, would installing the ZXpand (with it's own copy of the ROM) fix this, or does it still rely on the CS line from the ULA for it to work?