ZX Spectrums problems : diagnostic software ?
- 1024MAK
- Posts: 5124
- Joined: Mon Sep 26, 2011 10:56 am
- Location: Looking forward to summer in Somerset, UK...
Re: ZX Spectrums problems : diagnostic software ?
Do you mean a professional repairer?
Mark
Mark
ZX81 Variations
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.
Re: ZX Spectrums problems : diagnostic software ?
"Test" how? Resistance? Continuity? What results should I spect..
(I am on an issue 2 TS1016 rampack now)
Ernesto
ZX80 USA, ZX81UK, ZX Spectrum, ZX Spectrum+, ZX Spectrum 128+ UK, ZX Spectrum +2/A, Sinclair QL, CZ1000, CZ1500, CZ2000, CZ1000Plus, CZ1500Plus, CZ Spectrum, CZ Spectrum Plus, TK83, TK85, TK90X, TK95. TS2068. And more to come
ZX80 USA, ZX81UK, ZX Spectrum, ZX Spectrum+, ZX Spectrum 128+ UK, ZX Spectrum +2/A, Sinclair QL, CZ1000, CZ1500, CZ2000, CZ1000Plus, CZ1500Plus, CZ Spectrum, CZ Spectrum Plus, TK83, TK85, TK90X, TK95. TS2068. And more to come
- 1024MAK
- Posts: 5124
- Joined: Mon Sep 26, 2011 10:56 am
- Location: Looking forward to summer in Somerset, UK...
Re: ZX Spectrums problems : diagnostic software ?
Resistance. Pin 2 to pin 14 should be zero Ω or nearly zero Ω.
The other results should all be greater than 5kΩ.
Mark
ZX81 Variations
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.
Re: ZX Spectrums problems : diagnostic software ?
They are ok then.. I posted here.. viewtopic.php?f=7&t=3606&sid=e38b8fa285 ... e9345e11fd1024MAK wrote: ↑Tue Mar 17, 2020 3:28 pm Resistance. Pin 2 to pin 14 should be zero Ω or nearly zero Ω.
The other results should all be greater than 5kΩ.
Mark
Ernesto
ZX80 USA, ZX81UK, ZX Spectrum, ZX Spectrum+, ZX Spectrum 128+ UK, ZX Spectrum +2/A, Sinclair QL, CZ1000, CZ1500, CZ2000, CZ1000Plus, CZ1500Plus, CZ Spectrum, CZ Spectrum Plus, TK83, TK85, TK90X, TK95. TS2068. And more to come
ZX80 USA, ZX81UK, ZX Spectrum, ZX Spectrum+, ZX Spectrum 128+ UK, ZX Spectrum +2/A, Sinclair QL, CZ1000, CZ1500, CZ2000, CZ1000Plus, CZ1500Plus, CZ Spectrum, CZ Spectrum Plus, TK83, TK85, TK90X, TK95. TS2068. And more to come
Re: ZX Spectrums problems : diagnostic software ?
Pro or not. Anyone who has sufficient electronic knowledges to repair a Spectrum (in fact, I have two Spectrum to repair).
This afternoon I will try to replace TR3 as I have read somewhere that it is also involved in the RAM function.
I have also a TR6 on my Z80 (issue 2 motherboard), TR6 is there to correct a bug on ULA, so it should not be involved in my RAM problem, but I am wondering anyway ...
- 1024MAK
- Posts: 5124
- Joined: Mon Sep 26, 2011 10:56 am
- Location: Looking forward to summer in Somerset, UK...
Re: ZX Spectrums problems : diagnostic software ?
TR3 supplies the clock signal to the Z80. If TR3 is defective, the Z80 will do absolutely nothing and the machine will fail to start up (but you will get a screen of random colours and random pixels as the ULA may still be working).
I’ll point you in the direction of professional repairers later.
Mark
I’ll point you in the direction of professional repairers later.
Mark
ZX81 Variations
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.
Re: ZX Spectrums problems : diagnostic software ?
Mark, thanks a lot for your TR3 information.
Because of Covid19 I will not send my Spectrum's for repair before 4 or 5 months ... So before that I would like to try all I can to fix them.
I will soon (I hope) receive a new small oscilloscope. This one :
https://www.amazon.fr/gp/product/B077CZ ... U1VE1O4ZFQ
I never used any oscilloscope, so I will train myself to use it when received.
Will you be able to explain me how to use it to try test some components of my Spectrum ?
Because of Covid19 I will not send my Spectrum's for repair before 4 or 5 months ... So before that I would like to try all I can to fix them.
I will soon (I hope) receive a new small oscilloscope. This one :
https://www.amazon.fr/gp/product/B077CZ ... U1VE1O4ZFQ
I never used any oscilloscope, so I will train myself to use it when received.
Will you be able to explain me how to use it to try test some components of my Spectrum ?
Re: ZX Spectrums problems : diagnostic software ?
This "Oscilloscope" is no use for Sinclair stuff because its limited to 200khz.
Thats good for Audiosignals, but as the Sinclair oszillators are about 7 MHz the needed Oscilloscope will be twice of that (15MHz) at least. 20MHz analogue is ok for that. That is the usable frequency, not the sample rate. Sample rate in digital oscilloscopes need (again) be twice (better 5 times) the usage frequency (30megasample/second).
Its always good to go a little higher, so sample rates of 40megasample/second will be fine.
Examples are:
MongKok DSO168 or better Dastrues Digital Mini Oscilloscope 2.4 Inch https://www.amazon.fr/Oscilloscope-mini ... ljaz10cnVl
when staying with Amazon
Thats good for Audiosignals, but as the Sinclair oszillators are about 7 MHz the needed Oscilloscope will be twice of that (15MHz) at least. 20MHz analogue is ok for that. That is the usable frequency, not the sample rate. Sample rate in digital oscilloscopes need (again) be twice (better 5 times) the usage frequency (30megasample/second).
Its always good to go a little higher, so sample rates of 40megasample/second will be fine.
Examples are:
MongKok DSO168 or better Dastrues Digital Mini Oscilloscope 2.4 Inch https://www.amazon.fr/Oscilloscope-mini ... ljaz10cnVl
when staying with Amazon
In theory, there is no difference between theory and practice. But, in practice, there is.
Re: ZX Spectrums problems : diagnostic software ?
Thanks a lot for your quick answer, I will check that.
EDIT : AAaargh ! it's much more expensive ... As I do not know if I'll be able to use it in other cases than for the Spectrum ... I need to think about it ...
EDIT : AAaargh ! it's much more expensive ... As I do not know if I'll be able to use it in other cases than for the Spectrum ... I need to think about it ...
Last edited by dizzy33 on Thu Mar 26, 2020 12:26 pm, edited 1 time in total.
- 1024MAK
- Posts: 5124
- Joined: Mon Sep 26, 2011 10:56 am
- Location: Looking forward to summer in Somerset, UK...
Re: ZX Spectrums problems : diagnostic software ?
Do you have a 4020B or a 4060B CMOS Logic chip?
Mark
Mark
ZX81 Variations
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.
ZX81 Chip Pin-outs
ZX81 Video Transistor Buffer Amp
Standby alert
There are four lights!
Step up to red alert. Sir, are you absolutely sure? It does mean changing the bulb
Looking forward to summer later in the year.